| Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : SINOMATIC
Model Number : PY600-AZJ
Certification : CE/ ISO
Place of Origin : Shenzhen, China.
MOQ : Sample order accepted
Price : negotiable
Payment Terms : T/T,Western Union,L/C,D/A,D/P
Supply Ability : 10,000 pcs per month
Delivery Time : 5-10 working days after payment received
Packaging Details : Carton
Type : For AC Motor
Soft Start/Close Function : Yes
Limit Switch Setting : Yes
Automatic Close Time Setting : Yes
Auto-reverse Function : Yes
External button switch mode setting : Yes
AC Sliding Motor Control Board(PY600-AZ )
Power supply:110VAC/60Hz; 220VAC/50Hz
Soft start & Slow stop
Auto reverse function (need hall sensor) Auto close ; Pedestrian Mode
Support Photo sensor; Lamp; Extra button
DIP SWITCH
|
Number |
Function |
Description |
|
1 |
Soft Start/Close Function |
OFF–enabled ON–disabled Default position is OFF. |
|
2 |
Limit Switch Setting |
OFF–Normal Open ON–Normal Close Default position is OFF, this should align with limit switch and is not recommended to be modified by the users. |
|
3
|
Automatic Close Time Setting |
Automatic close time setting: the gate is operated to open by remote control operation and will close automatically after a few seconds delay. 3 OFF 4 ON: automatic close delay time is 12s. 3 ON 4 OFF: automatic close delay time is 24s. 3 ON 4 ON: automatic close delay time is 36s. 3 OFF 4 OFF: no automatic close function. Default setting: 3 OFF 4 OFF Disable the automatic close function. |
|
4
|
||
|
5 |
Auto-reverse Function |
OFF-enable ON-disable Default position is OFF, this should align with the opener status and is not recommended to be modified by the users. |
|
6 (optional) |
External button switch mode setting |
ON - External button switch is four button mode. OFF - External button switch is single button mode. |
Potentiometer Adjustment

VR1: Stall Force Mode
Maximum = More Force = Less sensitive
Minimum = Less Force = More sensitive
When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate opener will detect obstacles and impacts to the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise to decrease.
For safety, we strongly recommend that Stall Force Mode is left enabled (Dip switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position.
VR2: Brake Force Adjustment
For adjusting brake force at the limit position during gate opening and closing. This should only be adjusted for heavy gates that need additional force to brake when limit switch is detected.
Rotate VR2 clockwise to increase, counter-clockwise to decrease. Default setting is at minimum.
VR3: Slow Start/Stop Width Adjustment
This switch controls how many seconds the gate opener operates at maximum speed. Rotate VR3 clockwise to increase, rotate counter-clockwise to reduce.
When VR3 switches to minimum, slow start/stop function is disable.
VR4: Motor Output Force Adjustment
For best performance, set the torque at the lowest setting for secure use.
Rotate clockwise to increase, counter-clockwise to decrease.
Default setting is at maximum.
Terminal Instructions
J2 Terminal (as per Figure 15):
Terminal 6: External Push Button Pedestrian Switch
Terminal 5: External Open/Stop/Close/Stop Loop Control Push Button (Repeated Open/Stop/Close)
Terminal 4: Common Terminal for All External Control Push Button
Terminal 3: External Stop Push Button Switch.
Terminal 2: External Open Push Button Switch.
Terminal 1: External Close Push Button Switch.
J5 Terminal: Limit Switch and Accessories
Additional accessories sold separately
Terminal 13: Open Limit Switch
Terminal 12: Limit Switch Common Terminal
Terminal 11: Close Limit Switch
Terminal 10: Loop Detector Connector (Pre-wired by Factory)
Terminal 9: Ground/Earth (GND)
Terminal 8: Photocell input (N.C.). If no photocell is fitted, use a jumper between terminals 8 & 9.
Terminal 7: Power supply for accessories (+15V)
J6 Terminal:
Motor Capacitor
J4 Terminal:
MOT1: Motor Terminal, swap with MOT2 to change gate moving direction.
MOT2: Motor Terminal, swap with MOT1 to change gate moving direction.
MOTCOM: Motor Common Terminal.
LAMP (L&N): Connection for warning lamp.
PE: Motor and warning lamp earth
Note: If require to change the moving direction, not only MOT1 and MOT2 wires need to be swapped, but also the wires of 11 and 13 on J5 Terminal have to be swapped with each other.
J3 Terminal:
PE: Earth (yellow/green wire).
L: Power (brown wire).
N: Power (blue wire).

|
|
Soft Start And Slow Stop Function PY600-AZJ Sliding Gate Operator Control Board For AC Motor Images |